INPUT
Input Phase Single-Phase
Rated input current (Maximum Load) 10A
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type 5-15P
Input Circuit Breakers 10A
UPS Input Cord Length (ft.) 5
Recommended Electrical Service 15A 120V
OUTPUT
Output Capacity (VA) 750
Output Capacity (kVA) 0.75
Output Capacity (Watts) 450
Output Capacity (kW) 0.45
Output Capacity Details 6.3A @ 120V. 110%±10%,GOES TO FAULT AFTER 5MIN; 120%±10%,GOES TO FAULT IMMEDIATELY 110%±10%,SHUTS DOWN IN 5 SEC; 120%±10%, SHUTS DOWN IMMEDIATELY
Power Factor   0.6
Nominal Voltage Details 120V sinusoidal in line mode and 120V PWM in battery mode
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.
Output Voltage Regulation (Line Mode) 120V (±20%)
Output Voltage Regulation (Battery Mode) 120V (±10%)
UPS Output Receptacles (Surge Suppression Only) 6 UPS outlets, 6 surge-only outlets
Hot-Swap PDU options PDUB15 (2U / 8 5-15R outlets)
Output AC Waveform (AC Mode) Pure sine wave
Output AC Waveform (Battery Mode) PWM sine wave
Nominal Output Voltage(s) Supported 110V; 115V; 120V
Output Receptacles (12) 5-15R
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Runtime Full Load (min.)   2 min. (450W)
Runtime Half Load (min.)   8.6 min. (225W)
DC System Voltage (VDC) 12
Battery Recharge Rate (Included Batteries) 8 hours (10% to 90%)
Battery Access Battery access door
Internal UPS Replacement Battery Cartridge  RBC51 
Battery Replacement Description Replaceable internal batteries (see manual)
VOLTAGE REGULATION
Voltage Regulation Description Input voltage range of 95 to 145
USER INTERFACE, ALERTS & CONTROLS
Switches Switch controls power off/on status
Audible Alarm UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-battery conditions
LED Indicators Set of 3 status LEDs indicate operating mode, low-battery, overload, replace-battery and fault conditions
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 316
UPS AC Suppression Response Time Instantaneous
UPS Dataline Suppression 1 line TEL/DSL or Ethernet
EMI / RFI AC Noise Suppression   Yes
PHYSICAL
Primary Form Factor Desktop
Installation Form Factors Supported with Included Accessories Tower; Ultra-compact desktop; Wallmount
Primary UPS Depth (mm) 310
Primary UPS Height (mm) 85
Primary UPS Width (mm) 130
Shipping Dimensions (hwd / in.) 7.83 x 5.98 x 14.92
Shipping Weight (lbs.) 8.14
UPS Housing Material ABS
UPS Power Module Dimensions (hwd, in.) 3.35 x 5.12 x 12.2
UPS Power Module Weight (kg) 3.39
UPS Power Module Weight (lbs.) 7.48
Unit Weight (lbs.)

8.140

ENVIRONMENTAL
Operating Temperature Range 32° to 104°F (0° to 40°C)
Storage Temperature Range 5° to 113°F (-15° to 45°C )
Relative Humidity 0 to 90%, non-condensing
AC Mode BTU / Hr. (Full Load)   8.3
AC Mode Efficiency Rating (100% Load) >98%
Operating Elevation (ft.) 6561 ft. (2000 m) above sea level
Operating Elevation (m) Up to 3000m
COMMUNICATIONS
PowerAlert Software For local monitoring via the UPS’s built-in USB port, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
Communications Cable USB interface cable included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card Description Network management not supported
Communications Interface USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time   6 milliseconds typical (10 milliseconds max)
Low Voltage Transfer to Battery Power (Setpoint) 95
High Voltage Transfer to Battery Power (Setpoint) 145
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features   Surge/noise protection
Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS
APPLICATIONS
UPS Applications Computer/Peripherals; Audio/Video; Retail/Point of Sale; Hospitality
STANDARDS & COMPLIANCE
Product Certifications RETIE (Colombia); CSA (Canada); NOM (Mexico); UL 1778